Technical data - electrical ratings
Shaft insulation
Suitable up to 2.8 kV
Transmission length
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Interference immunity
EN 61000-6-2
Emitted interference
EN 61000-6-3
Approval
CE
Technical data - electrical ratings (encoder)
Voltage supply
9...30 VDC; 5 VDC ±5 %
Consumption w/o load
≤100 mA
Pulses per revolution
300 … 5000
Phase shift
90 ° ±20°
Duty cycle
40…60 %
Reference signal
Zero pulse, width 90°
Output frequency
≤120 kHz
≤300 kHz (on request)
Output signals
K1, K2, K0 + inverted
Error output (option EMS)
Output stages
HTL-P (power linedriver)
TTL/RS422
Sensing method
Optical
Technical data - electrical ratings (centrifugal switch)
Switching accuracy
± 4 % (Δn = 2 rpm/s);
20 % (Δn = 1500 rpm/s)
Switching deviation
≤3 % (cw-ccw rotation)
Switching hysteresis
40 % of switching speed
Switching outputs
1 output, speed control
Output switching capacity
≤6 A / 230 VAC
≤1 A / 125 VDC
(EAC: <50 VAC / 75 VDC)
Minimum switching current
50 mA
Technical data - mechanical design
Size (flange)
ø105 mm
Shaft type
ø16...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
Admitted shaft load
≤450 N axial
≤600 N radial
Protection EN 60529
IP 67
Speed (n)
≤1.25 · ns
Range of switching speed (ns)
850...4500 rpm (Δn = 2 rpm/s)
Operating torque typ.
6 Ncm
Rotor moment of inertia
680 gcm²
Material
Housing: aluminium die-cast
Shaft: stainless steel
Operating temperature
-40...+100 °C
-25...+100 °C (>3072 pulses)
-50...+100 °C (optional)
Resistance
IEC 60068-2-6
Vibration 5 g, 10-2000 Hz
IEC 60068-2-27
Shock 50 g, 11 ms
Corrosion protection
IEC 60068-2-52 Salt mist
for ambient conditions CX (C5-M) according to ISO 12944-2
Connection
2x terminal box
3x terminal box (with option M)
Weight approx.
2.2 kg
2.4 kg (with option M)