Technical data - electrical ratings
Voltage supply
9...30 VDC
Consumption w/o load
≤100 mA
Pulses per revolution
1024
Phase shift
90 ° ±20°
Duty cycle
40…60 %
Reference signal
Zero pulse, width 90°
Sensing method
Optical
Output frequency
≤120 kHz
Output signals
K1, K2, K0 + inverted
Output stages
HTL-P (power linedriver)
Interference immunity
EN 61000-6-2
Emitted interference
EN 61000-6-3
Approval
CE
UL approval / E217823
Technical data - mechanical design
Size (flange)
ø115 mm
Shaft type
ø11 mm solid shaft
Admitted shaft load
≤300 N axial
≤450 N radial
Flange
EURO flange B10
Protection EN 60529
IP 66
Operating speed
≤12000 rpm (mechanical)
Operating torque typ.
2 Ncm
Rotor moment of inertia
212 gcm²
Material
Housing: aluminium die-cast
Shaft: stainless steel
Operating temperature
-40...+100 °C
Resistance
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
Corrosion protection
IEC 60068-2-52 Salt mist
for ambient conditions CX (C5-M) according to ISO 12944-2
Connection
Terminal box
Weight approx.
3.1 kg