Technical data - electrical ratings
Voltage supply
9...30 VDC
5 VDC ±5 %
Consumption w/o load
≤100 mA
Pulses per revolution
300 … 2500
Phase shift
90 ° ±20°
Duty cycle
30…70 %
Reference signal
Zero pulse, width 90°
Sensing method
Optical
Output frequency
≤120 kHz
Output signals
K1, K2, K0 + inverted
Output stages
HTL-P (power linedriver)
TTL/RS422
Transmission length
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Interference immunity
EN 61000-6-2
Emitted interference
EN 61000-6-3
Approval
CE
UL approval / E217823
DNV approval
Location classes DNV
Temperature: D
Humidity: B
Vibration: B
EMC: B
Enclosure: C
Technical data - mechanical design
Size (flange)
ø105 mm
Shaft type
ø16 mm (blind hollow shaft)
Admitted shaft load
≤250 N axial
≤400 N radial
Protection EN 60529
IP 67
Operating speed
≤6000 rpm (mechanical)
Operating torque typ.
6 Ncm
Rotor moment of inertia
340 gcm²
Material
Housing: aluminium die-cast
Shaft: stainless steel
Operating temperature
-40...+100 °C
Resistance
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
Corrosion protection
IEC 60068-2-52 Salt mist
for ambient conditions CX (C5-M) according to ISO 12944-2
Connection
Terminal box
Weight approx.
1.6 kg