Technical data - electrical ratings
Voltage supply
9...30 VDC
5 VDC ±5 %
Consumption w/o load
≤100 mA
Pulses per revolution
300 … 5000
Phase shift
90 ° ±20°
Duty cycle
40…60 %
Reference signal
Zero pulse, width 90°
Sensing method
Optical
Output frequency
≤120 kHz
≤300 kHz (on request)
Output signals
K1, K2, K0 + inverted
Error output (option EMS)
Output stages
HTL-P (power linedriver)
TTL/RS422
Shaft insulation
Suitable up to 2.8 kV
Transmission length
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Interference immunity
EN 61000-6-2
Emitted interference
EN 61000-6-3
Approval
CE
UL approval / E217823
Technical data - mechanical design
Size (flange)
ø105 mm
Shaft type
ø12...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
Admitted shaft load
≤450 N axial
≤600 N radial
Protection EN 60529
IP 67
Operating speed
≤6000 rpm (mechanical)
Operating torque typ.
6 Ncm
Rotor moment of inertia
340 gcm²
Material
Housing: aluminium die-cast
Shaft: stainless steel
Operating temperature
-40...+100 °C
-25...+100 °C (>3072 pulses)
-50...+100 °C (optional)
Resistance
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
Corrosion protection
IEC 60068-2-52 Salt mist
for ambient conditions CX (C5-M) according to ISO 12944-2
Explosion protection
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Connection
Terminal box
Terminal cover
2x terminal box (with option M)
Weight approx.
1.6 kg
1.8 kg (with option M)