Voltage supply
8...30 VDC
14...30 VDC
Reverse polarity protection
Yes
Consumption typ.
20 mA (24 VDC, w/o load)
Initializing time
≤ 170 ms after power on
Response time
< 1 ms
Interface
Analog 0...10 V / 0.5...4.5 V / 4...20 mA / Resolution: 12 bit
Function
Multiturn
Singleturn
Teach range
5°...359.9° (singleturn)
5°...32767 turns (multiturn)
Absolute accuracy
±0.15 ° (+20 ±15 °C)
±0.25 ° (-40...+85 °C) sensor
Accuracy analog output
±0.5 % of whole measuring range (-40...+85 °C)
Sensing method
Magnetic
Interference immunity
EN 61000-6-2
ISO 11452-2:2004* / -5:2002*
ISO 7637-2:2004*
ISO 10605:2008 + Amd 1:2014 (CD ±8 kV / AD ±15 kV)
* Severity level according to ECE R10 (Rev. 4)
Emitted interference
EN 61000-6-4
CISPR 25:2008 (30...1000 MHz)
ISO 7637-2:2004*
* Severity level according to ECE R10 (Rev. 4)
MTTFd (ISO 13849)
High (>100 years)
Use in safety functions exclusively based on Application Note and MTTFd reliability prediction (request separately).
Programmable parameters
Measuring range teachable
Diagnostic function
DATAVALID
Factory setting
360° and 10 revolutions (other on request)
Approval
UL approval / E217823