Voltage supply
4.5…30 VDC (SSI, SSI + TTL/RS422)
5.5…30 VDC (SSI + HTL/Push-pull)
Consumption typ.
60 mA (5 VDC, w/o load)
20 mA (24 VDC, w/o load)
Initializing time
≤170 ms after power on
Data currency
Typ. 2 µs (cyclic request)
Interface
SSI
SSI + incremental
Function
Multiturn
Singleturn
Operating mode
Linear feedback shift register (on request)
Steps per revolution
≤16384 / 14 bit
Number of revolutions
≤262144 / 18 bit
Absolute accuracy
±0.15 ° (+20 ±15 °C)
±0.25 ° (-40...+85 °C)
Sensing method
Magnetic
Code
Gray or binary
Code sequence
CW: ascending values with clockwise sense of rotation; looking at flange
Inputs
SSI clock: Linereceiver RS422
Zero setting input
Counting direction
Output stages
SSI data: Linedriver RS422
Incremental: linedriver RS422 or push-pull (option)
Incremental output
1024, 2048, 4096 ppr (other on request)
Output signals
A+, A-, B+, B-
Output frequency
≤350 kHz
Interference immunity
EN 61000-6-2
Emitted interference
EN 61000-6-4
Diagnostic function
DATAVALID (on request)
Approval
UL approval / E217823