Voltage supply
10...30 VDC
Consumption typ.
20 mA (24 VDC, w/o load)
Initializing time
≤170 ms after power on
Interface
CANopen®
SAE J1939
Function
Multiturn
Singleturn
Profile conformity
CANopen® CiA communication profile DS 301, LSS profile DSP 305, device profile DS 406
Steps per revolution
≤16384 / 14 bit
Number of revolutions
≤262144 / 18 bit
Absolute accuracy
±0.15 ° (+20 ±15 °C)
±0.25 ° (-40...+85 °C) (see info working distance)
Sensing method
Magnetic
Code sequence
CW: ascending values with clockwise sense of rotation; looking at flange
Output stages
CAN-Bus, LV (3.3 V) compatible ISO 11898
Interference immunity
EN 61000-6-2
ISO 11452-2:2004* / -5:2002*
ISO 7637-2:2004*
ISO 10605:2008 + Amd 1:2014 (CD ±8 kV / AD ±15 kV)
* Severity level according to ECE R10 (Rev. 4)
Emitted interference
EN 61000-6-4
CISPR 25:2008 (30...1000 MHz)
ISO 7637-2:2004*
* Severity level according to ECE R10 (Rev. 4)
MTTFd (ISO 13849)
High (>100 years)
Use in safety functions exclusively based on Application Note and MTTFd reliability prediction (request separately).
Approval
UL approval / E217823