WMK 2010 S Standard
Scanning head for modular angle encoders
Scanning arrangement: Outside scanning
Measuring method: incremental
Measuring principle: inductive
Design of the scanning Standard, cable outlet
head: right
Line count: 900
Number of signal
periods: 900
Grating period: 1000 µm
Interface: ~1 Vpp
Incremental signals /
multiplication: without
Safety concept: Analog signals (1 Vpp) can
be used for safety-related
equipment
Max. scanning frequency:100.00 kHz
Power supply: 4 V ... 7 V DC
Electrical connection: Angle flange socket, M23
SpeedTEC, nickel-plated,
bolt circle diameter 28
mm, with vibration O-ring,
17 x 1.5 mm, male, 17-pin
Pin configuration: D1216449
Cable length: 0.15 m
Included part and Connector included
packaging: separately