Grating period
40.000 µm
Reference mark
Reference mark active
Reference pulse width
90°
Minimum edge separation
0.100 µs
Power supply
5 V (+-10 %)
Output signal
Square-wave signals, TTL levels
with 100-fold interpolation
Limit switch
Open collector - activ high
impedance
Limit switch 2
Open collector - activ high
impedance
Cable length
4.00 m
Electrical connection
D-sub connector, metal
housing, 3-row, with locking screws, male, 15-pin
Pin configuration
D1158394