LMK 2010 HA High Accuracy
Measuring method: incremental
Measuring principle: inductive
Design of the scanning Standard, flat design,
head: higher design for limit
switch evaluation, cable
outlet right
Grating period: 1000 µm
Interface: TTL
Incremental signals /
multiplication: 2500 fold
Signal period: 0.400 µm
Max. scanning frequency:1.00 kHz
Power supply: 5 V (+-10 %) DC
Electrical connection: D-sub connector, 2-row,
with locking screws, male,
15-pin
Pin configuration: D1236409
Cable length: 0.50 m
Special characteristics,
scanning head: Edge separation >= 0.1 µs
Included part and Supplementary material
packaging: 5300011